»ó¼¼ ¼³¸í

In addition to standard polystyrene calibration films, ICL offers several other calibration options.
Superior calibrations are performed with radially symmetric films which eliminate the orientation effects of extruded films used for NIST Standard 1921 calibrations.

This makes the films consistent from film to film. Sold in pairs of two (2) different film thickness,
the differential between the absorbance intensities created by the two (2) film thickness becomes the baseline,
thereby making the pair of films suitable both as an ordinate calibration standard useful for detection of degradation in instrument performance and
for calibrating the abscissa scale in accordance with NIST Standard 1921.

Films are available in free standing pairs mounted on 2¡± x 4¡± cards that fit in the standard universal slide mount in all spectrophotometers or the films can be cast on KBr windows.
Films cast on KBr windows will not exhibit any interference fringes.
KBr windows with films are sold with a mount with a 2¡± x 3¡± backplate that fits the standard universal slide mount in all spectrophotometers.
The polystyrene coating prevents degradation of the KBr window from moisture effects. Boron doped crystal windows are also available as calibration standards.
These windows can be matched in pairs with comparable absorbances. PhEur 2.2.24 films are described in a separate section.
»ó¼¼ ±Ô°Ý
Cat. No. Model Discription
F11-87-708 00092500 Polystyrene Test Film 38 microns
F11-87-711 00098181 76 microns
Cat. No. Model Discription
F11-87-801 00098182 Pair Polystyrene Test Film (38 microns + 76 microns)
F11-87-705 00098487 Same as 0009-8182, but with PhEur 2.2.24 certified films
* 00098182

- With cerfication of tracebility to five(5) NIS 1921b frequencies

- The second film (76 microns) is provided without certification.

- Both films are mounted on 2" x 3" cardstock holder with a 19mm aperture for mounting in the universal slide holder in all instruments.

- Available with PhEur 2.2.24 certified polystyrene calibration film 


* 00098487

- With PhEur 2.2.24 certified film.



Cat. No. Model Discription
F11-87-806 00097676 NIST traceable Polystyrene Test film
NIST traceable Polystyrene Test film, certificate of traceability to five (5) NIST 1921b frequencies, set of 2 films each mounted to 2¡± x 4¡± cardstock holder


Cat. No. Model Discription
F11-87-809 00097393 Pair of polystyrene films
Pair of polystyrene films of different thickness, both with NIST traceability certification. Kit also includes a pair of standard polystyrene films, but without NIST traceability certification.

One NIST traceable film is mounted on 2" x 4" cardstock, which enables mounting in the standard universal slide mount found in all spectrophotometers, and is the same thickness as an NIST 1921 standard film (38 microns).

The second thinner NIST traceable film is cast on KBr and includes holder and mounting device.

Kit includes certification of traceability to five (5) NIST 1921b frequencies, radial symmetry certification for film cast on KBr and storage cases for all films.


Cat. No. Model Discription
F11-87-815 00097394 Pair of polystyrene calibration films
Pair of polystyrene calibration films of different thickness cast on KBr, radial symmetry certification, summary of NIST standard 1921 with frequency locations, certification of traceability to five (5) NIST 1921b frequencies,

instructions for two (2) film ordinate calibration, slide mount holder.

Kit also includes a pair of standard polystyrene films, without NIST traceability certification, mounted on 2" x 4" cardstock which enables mounting in the standard universal slide mount found in all spectrophotometers. Storage case provided

Cat. No. Model Discription
F11-87-818 00099247 Pair of 13mm x 2mm KBr windows
Pair of 13mm x 2mm KBr windows intended to fit FTIR microscope stage, coated with polystyrene and certified to five (5) NIST 1921b frequencies


Cat. No. Model Discription
F11-87-821 00097395 Single Boron doped KBr Crystal
Single Boron doped KBr Crystal calibration standard with slide mount holder and storage case. (U.S. Patent No. 6,594,008)



Cat. No. Model Discription
F11-87-824 00097396 Pair of matched Boron doped KBr windows
*U.S. Patent No. 6,594,008


Cat. No. Model Discription
F11-87-827 00098157 Polystyrene calibration film
F11-87-830 00098158 same as 0009-8157 but with 2 certified films
* Polystyrene calibration film for PhEur 2.2.24 calibration of IR and FTIR instruments, certified to 7 wave-numbers and certified as to absorption minima and maxima differentials at 2870 cm-1 and 2849.5cm-1 and at 1589 cm-1 and 1583 cm-1


Cat. No. Model Discription
F11-87-833 00098559 Polystyrene calibration film
F11-87-836 00098558 same as 0009-8559 but with 2 certified Films
* Polystyrene Calibration film for PhJap 2.25 calibration of IR and FTIR instruments, certified to 7 wave numbers, mounted on 2" x 4" card stock


Cat. No. Model Discription
F11-87-838 00098560 Polystyrene calibration film
* Polystyrene calibration film, certificate of traceability to seven (7) NIST frequencies (wave numbers) and certified as to absorption minima and maxima differentials at 2870cm-1 and 2849.5cm-1 and 1589cm-1 and 1583cm-1 as required by PhEur 2.2.24


Cat. No. Model Discription
F11-87-841 00098448 Polystyrene calibration film
F11-87-843 00098437 Pair of films same as 0009-8448
* Polystyrene calibration film, certificate of traceability to seven (7) NIST frequencies (wave numbers) and certified as to absorption minima and maxima differentials at 2870cm-1 and 2849.5cm-1 and 1589cm-1 and 1583cm-1 as required by PhEur 2.2.24 and also certified to PhJap 2.25


Cat. No. Model Discription
F11-87-845 00099248 Custom Cut Polystyrene film
* Custom Cut Polystyrene film cut to the size of any Horizontal ATR accessory (please specify, up to 4" square), certified to five (5) NIST 1921b frequencies