»ó¼¼ ±Ô°Ý
  • Vertical lift stages with built-in controllers
»ó¼¼ ±Ô°Ý Ç¥
Cat. No. Model Description
M01-680-725 X-VSR20A-KX13A   Motorized lift stage, 20 mm travel, integrated controller, plus manual control
M01-680-730 X-VSR40A-KX13A   Motorized lift stage, 40 mm travel, integrated controller, plus manual control
M01-680-735 VSR20A-T3-MC03 Motorized lift stage, 20 mm travel, fine resolution
M01-680-740 VSR40A-T3-MC03 Motorized lift stage, 40 mm travel, fine resolution
  • Vertical lift stages with built-in controllers Specification
»ó¼¼ ±Ô°Ý Ç¥
Specification
Value Value
Model X-VSR Series VSR Series
Feature Motorized Vertical Stages with Built-in controllers Motorized Vertical Stage
Microstep Size (Default Resolution) 0.09525 µm 0.09525 µm
Built-in Controller Yes No, X-MCB1 (48 V) Recommended
Accuracy (unidirectional) 35 µm 35 µm
Repeatability < 1 µm < 1 µm
Loaded Backlash (10 N) < 10 µm < 10 µm
Maximum Speed 48 mm/s 48 mm/s
Peak Thrust 200 N 200 N
Maximum Continuous Thrust 100 N 100 N
Communication Interface RS-232  
Communication Protocol Zaber ASCII (Default), Zaber Binary  
Maximum Centered Load 100 N 100 N
Maximum Cantilever Load 300 N-cm 300 N-cm
Pitch 0.08 degrees 0.08 degrees
Roll 0.08 degrees 0.08 degrees
Maximum Current Draw 950 mA  
Power Supply 24-48 VDC  
Power Plug 2-pin Screw Terminal  
Linear Motion Per Motor Rev 1.2182 mm 1.2192 mm
Motor Steps Per Rev 200 200
Motor Type Stepper (2 phase) Stepper (2 phase)
Motor Rated Current 1500 mA/phase 1500 mA/phase
Inductance 1.9 mH/phase 1.9 mH/phase
Default Resolution 1/64 of a step  
Data Cable Connection Locking 4-pin M8 1/64 of a step
Mechanical Drive System Precision Lead Screw Precision Lead Screw
Limit or Home Sensing Magnetic home sensor Magnetic home sensor
Manual Control Yes
Axes of Motion 1 1
Mounting Interface M6 and M3 threaded holes M6 and M3 threaded holes
Travel Range 20 ~ 40 mm 20 ~ 40 mm
Backlash <35 um or <120 um <35 um or <120 um