¢ºASR-E Series: Closed-loop motorized XY scanning stages with built-in motor encoders
  ¡á 50 mm up to 120 mm travel per axis
  ¡á Easily adjustable non-contact hall sensor limit switches
  ¡á 12 µm accuracy; 2 µm repeatability; 85 mm/s speed
  ¡á Supported by µManager and MetaMorph¢ç Microscopy Automation & Image Analysis Software

¢ºASR Series: Motorized XY microscope stages
  ¡á 50 mm up to 120 mm travel per axis
  ¡á Easily adjustable non-contact hall sensor limit switches
  ¡á 12 µm accuracy; 2 µm repeatability; 85 mm/s speed
  ¡á Supported by µManager and MetaMorph¢ç Microscopy Automation & Image Analysis Software
»ó¼¼ ±Ô°Ý
  • Scanning & Microscope Stages
»ó¼¼ ±Ô°Ý Ç¥
Cat. No. Model Description
M01-680-940 ASR050B050B-E03T3-K0047 Closed-loop motorized XY scanning stage, 50 mm x 50 mm travel, X-MCB2 (48 V) Recommended
M01-680-943 ASR050B050B-E03T3-K0062 Closed-loop motorized XY scanning stage, 50 mm x 50 mm travel, X-MCB2 (48 V) Recommended
M01-680-946 ASR100B120B-E03T3-K0045 Closed-loop motorized XY scanning stage, 100 mm x 120 mm travel, X-MCB2 (48 V) Recommended
M01-680-949 ASR100B120B-E03T3-K0046 Closed-loop motorized XY scanning stage, 100 mm x 120 mm travel, X-MCB2 (48 V) Recommended
M01-680-952 ASR100B120B-E03T3-K0047 Closed-loop motorized XY scanning stage, 100 mm x 120 mm travel, X-MCB2 (48 V) Recommended
M01-680-955 ASR100B120B-E03T3-K0056 Closed-loop motorized XY scanning stage, 100 mm x 120 mm travel, X-MCB2 (48 V) Recommended
M01-680-958 ASR050B050B-T3-K0047 Motorized XY microscope stage, 50 mm x 50 mm travel, X-MCB2 (48 V) Recommended
M01-680-961 ASR050B050B-T3-K0062 Motorized XY microscope stage, 50 mm x 50 mm travel, X-MCB2 (48 V) Recommended
M01-680-964 ASR100B120B-T3-K0045 Motorized XY microscope stage, 100 mm x 120 mm travel, X-MCB2 (48 V) Recommended
M01-680-967 ASR100B120B-T3-K0046 Motorized XY microscope stage, 100 mm x 120 mm travel, X-MCB2 (48 V) Recommended
M01-680-970 ASR100B120B-T3-K0047 Motorized XY microscope stage, 100 mm x 120 mm travel, X-MCB2 (48 V) Recommended
M01-680-973 ASR100B120B-T3-K0056 Motorized XY microscope stage, 100 mm x 120 mm travel, X-MCB2 (48 V) Recommended
  • Scanning & Microscope Stages Specification
»ó¼¼ ±Ô°Ý Ç¥
Specification
Value Value
Model ASR-E series ASR series
Microstep Size (Default Resolution) 0.15625 µm 0.15625 µm
Built-in Controller No No
Recommended Controller X-MCB2 (48 V) Recommended X-MCB2 (48 V) Recommended
Accuracy (unidirectional) 12 µm 12 µm
Repeatability < 2 µm < 2 µm
Backlash < 4 µm < 4 µm
Maximum Speed 85 mm/s 85 mm/s
Minimum Speed 0.000095 mm/s 0.000095 mm/s
Speed Resolution 0.000095 mm/s 0.000095 mm/s
Encoder Type Motor mounted rotary quadrature encoder  
Peak Thrust 95 N 95 N
Maximum Continuous Thrust 95 N 95 N
Guide Type Crossed roller bearing Crossed roller bearing
Pitch 0.02 degrees 0.02 degrees
Roll 0.02 degrees 0.02 degrees
Yaw 0.005 degrees 0.005 degrees
Linear Motion Per Motor Rev 2.00 mm 2.00 mm
Motor Steps Per Rev 200 200
Motor Type Stepper (2 phase) Stepper (2 phase)
Motor Rated Current 670 mA/phase 670 mA/phase
Motor Winding Resistance 9.2 ohms/phase 9.2 ohms/phase
Inductance 5.6 mH/phase 5.6 mH/phase
Motor Rated Power 4.2 Watts 4.2 Watts
Motor Connection D-sub 15 D-sub 15
Mechanical Drive System Precision lead screw Precision lead screw
Limit or Home Sensing Magnetic, adjustable home and away sensors Magnetic, adjustable home and away sensors
Axes of Motion 2 2
Mounting Interface Separate mounting adaptors available Separate mounting adaptors available
Operating Temperature Range 0 to 50 degrees C 0 to 50 degrees C
RoHS Compliant Yes Yes
CE Compliant Yes Yes